What is the recommended distance that a vent connector should slope upward?

1/8 inch per foot

1/4 inch per foot

The recommended distance that a vent connector should slope upward is 1/4 inch per foot. This specific slope is important because it helps ensure the efficient movement of flue gases away from appliances and reduces the risk of condensation within the vent system. When the vent connector slopes upward at this rate, it promotes proper drainage of any moisture that may accumulate, which is crucial for maintaining the integrity of the venting system and preventing blockages. This standard is established to enhance safety and efficiency in the venting process, as faulty venting can lead to hazardous conditions, including the potential buildup of carbon monoxide.

In contrast, other options may not provide the necessary drainage or could lead to improper venting. An insufficient slope might allow condensate to pool in the vent, potentially leading to corrosion or obstruction, while a steeper slope could create challenges in maintaining a proper flow of exhaust gases. Therefore, the guideline of 1/4 inch per foot is widely accepted and recommended within the industry.